Do you know what common instruments/meters are needed for reverse osmosis systems?

Views : 65
Author : Susan
Update time : 2024-09-29 16:27:17
Do you know what common meters are needed for reverse osmosis systems?Today Susan to answer some questions for you about water treatment equipment, I hope to be able to help you.
In order to make the RO device can be safe and reliable operation, easy to monitor the operation process, should be equipped with the necessary instrumentation and control devices, generally need to install the instrumentation has a temperature meter, flow meter, pressure meter, conductivity meter, oxidation potential meter, chlorine meter, pH meter, specific as follows:

1. temperature meter:
Feed water temperature meter, because the water production is related to the temperature, so it needs to be tested in order to find out the standardized water production, large-scale equipment should be recorded, in addition, the temperature exceeds 45 ℃ will damage the membrane element, so the raw water heater system should be set up to exceed the limit of the alarm, over the limit of the automatic drainage and shutdown RO protection.

2. Pressure gauge:
The feed water pressure gauge, the first section RO effluent pressure gauge, and the drain pressure gauge are used to calculate the pressure drop in each section and to standardize the water production and salt transmission rate. Salt transmission rate, water yield and Δp are used to analyze RO performance problems.
The 5um filter should be installed with inlet and outlet pressure gauges, and when the pressure drop reaches a certain value, the filter element needs to be replaced.
Inlet and outlet pressure gauges for feed pumps, inlet and outlet pressure switches are used to shut down the pump when the inlet pressure is low and to stop the pump when the outlet pressure is high.

3. flow meter:
Product water flow meter in operation to detect the amount of water produced, each section should be installed separately, in order to standardize RO performance data.
Product water flow rate should be indicated, totalized and recorded. Concentrated water drainage flow meter detects drainage during operation and shall be indicated cumulative and recorded. From the product flow rate and drainage flow rate can be calculated from the sections of the water supply, recovery rate and the recovery rate of the entire RO, feed water flow meter is mainly used for RO dosage of automatic adjustment, in addition to indicating the cumulative signal should also be given for proportional adjustment.

4. conductivity meter:
Feed water conductivity meter, water conductivity meter indicates and records the conductivity of water: alarms can be set, and the desalination rate can be calculated from the conductivity of feed water and the conductivity of produced water.

5. pH meter
When acid is added to the feed water to prevent CaCO3 from forming scale, a pH meter should be installed in the feed water after acid is added.

6. chlorine meter
Chlorine meter is installed in the feed water to control the chlorine content of the feed water.

7. Oxidation potential meter
By adding sodium bisulfite to eliminate chlorine residual feed water should be equipped with redox point meter, there should be an indication of the record, exceed the limit alarm.

The above is the general knowledge of water treatment equipment, I hope you can help you, if you want to know more about the general knowledge of water treatment, welcome to leave a message in the comments section, I will try to reply, if you want to watch more water treatment knowledge please contact me through the following business card. Thank you for reading and have a nice life!


 
Related News
Read More >>
Does your reverse osmosis equipment often wash the membrane, change the membrane? Does your reverse osmosis equipment often wash the membrane, change the membrane?
Sep .27.2024
Users reflecting their own purchase of reverse osmosis equipment frequently wash membrane, reverse osmosis membrane use life is short and other issues. Today Susan organized a compilation of reverse osmosis equipment for reference, welcome to exchange, correction.
Do you know what you should do when the water purification equipment has a low water output rate? Do you know what you should do when the water purification equipment has a low water output rate?
Sep .26.2024
Today, Susan will give you a detailed answer to this question: Under normal circumstances, the phenomenon of low water output rate and high voltage of water purification equipment is mainly due to It is caused by instrument readings, temperature, inlet water conductivity, potential water side pressure, pressure difference, membrane element attenuation, membrane element pollution, untimely maintenance, etc.
Do you know the difference between ultrafiltration membrane and ro reverse osmosis membrane? And How to choose them? Do you know the difference between ultrafiltration membrane and ro reverse osmosis membrane? And How to choose them?
Sep .25.2024
Ultrafiltration membrane and 0 reverse osmosis membrane are both industrial filter membrane, in the production of industrial water filtration have a great role, but these two membrane elements are different in many ways. Understand the difference between the two before you can make a better choice.